Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Neurosci Methods ; 402: 110016, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37995854

RESUMEN

BACKGROUND: Neuropixels probes have revolutionized neurophysiological studies in the rodent, but inserting these probes through the much thicker primate dura remains a challenge. NEW METHODS: Here we describe two methods we have developed for the insertion of two types of Neuropixels probes acutely into the awake macaque monkey cortex. For the fine rodent probe (Neuropixels 1.0, IMEC), which is unable to pierce native primate dura, we developed a dural-eyelet method to insert the probe repeatedly without breakage. For the thicker short NHP probe (Neuropixels NP1010), we developed an artificial dura system to insert the probe. RESULTS AND COMPARISON WITH EXISTING METHODS: We have now conducted successful experiments in 3 animals across 7 recording chambers with the procedures described here and have achieved recordings with similar yields over several months in each case. CONCLUSION: We hope that our hardware, surgical preparation, methods for insertion and methods for removal of broken probe parts are of value to primate physiologists everywhere.


Asunto(s)
Corteza Cerebral , Vigilia , Animales , Haplorrinos , Corteza Cerebral/fisiología , Neurofisiología , Electrodos Implantados
2.
bioRxiv ; 2023 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-37425930

RESUMEN

Neuropixels probes have revolutionized neurophysiological studies in the rodent, but inserting these probes through the much thicker primate dura remains a challenge. Here we describe two methods we have developed for the insertion of two types of Neuropixels probes acutely into the awake monkey cortex. For the fine rodent probe, which is unable to pierce native primate dura, we developed a dural-eyelet method to insert the probe repeatedly without breakage. For the thicker NHP probe, we developed an artificial dura system to insert the probe. We have now conducted successful experiments in 3 animals across 7 recording chambers with the procedures described here and have achieved stable recordings over several months in each case. Here we describe our hardware, surgical preparation, methods for insertion and methods for removal of broken probe parts. We hope that our methods are of value to primate physiologists everywhere.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...